Linux ACP Modem (Mwave) mini-HOWTO by Mike Sullivan (white hot kiss TXT) 📕
The above command should return the following for serial port 1:
+---------------------------------------------------------------------------+ |/dev/ttyS1, UART: 16550A, Port: 0x2f8, IRQ: 3 | +---------------------------------------------------------------------------+
The port and IRQ numbers should match the information placed in the syslog by the ACP module when it was loaded: kernel: Mwave Modem, UART settings IRQ 0x3 IO 0x2f8
If the information returned by setserial indicates that the UART is 'unknown' or if the IRQ and I/O resources do not match what you have in the syslog, you will need to reconfigure. Check the setserial man pages to learn how to setup the resources on your ttySx to match what appears in the syslog output.
If you have problems running setserial, you may have a resource conflict. Before using insmod mwave, check /proc/ioports and /proc/interrupts to make sure the resources
Read free book «Linux ACP Modem (Mwave) mini-HOWTO by Mike Sullivan (white hot kiss TXT) 📕» - read online or download for free at americanlibrarybooks.com
- Author: Mike Sullivan
- Performer: -
Read book online «Linux ACP Modem (Mwave) mini-HOWTO by Mike Sullivan (white hot kiss TXT) 📕». Author - Mike Sullivan
Linux ACP Modem (Mwave) mini-HOWTO
Mike Sullivan
Paul Schroeder
Joy Yokley - Edited document and coverted to DocBook v4.1 (SGML).
2001-01-12
Revision History
Revision .11 2002-07-18 Revised by: PBS
Revision .10 2001-07-18 Revised by: PBS
Revision .09 2001-05-21 Revised by: PBS
Revision .08 2001-05-09 Revised by: JEY
Revision .07 2001-04-30 Revised by: JEY
This document describes how to build, setup, and use the driver and user
space application necessary for using the ACP (Mwave) Modem in the IBM
Thinkpad?? 600, 600E, and 770 models which include the on board ACP modem
hardware. The latest version of this document can always be found at [http://
www.ibm.com/linux/ltc/] http://www.ibm.com/linux/ltc/
Table of Contents
General Information and Hardware Requirements
1.1. Introduction
1.2. Credits
1.3. Where Can I Get the Latest Version of this Driver?
1.4. Are There Any Other Resources?
1.5. Copyright Notice and Disclaimer
1.6. Which Systems are Supported
1.7. Features of the Modem
Compilation, Installation, and Startup
2.1. Prerequisites
2.2. Building and Installing Source
2.3. Setting Things Up
2.4. Runtime
Resolving Installation and Configuration Problems
3.1. DSP Does Not Start
3.2. Resource Conflicts
3.3. Not Connecting at Specified Starting Speed
3.4. Dialer Application Cannot Detect Serial Port
3.5. PPP Errors Using 2.4.0 Version of the Kernel
Debugging Tips
4.1. Error Logs
4.2. Tracing
Test Claims
List of Supported Countries
Trademarks
General Information and Hardware Requirements
1.1. Introduction
The ACP Modem for Linux is a software based modem. Support software for the
ACP modem is composed of a loadable kernel module and a user level
application. Together these components support direct connection to public
switched telephone networks (PSTNs) and support selected countries world
wide. Refer to Section 6 of this document for the supported country list.
The modem also supports the standard communications port interface (ttySx)
and is compatible with the Hayes AT Command Set.
ACP Modem software is continually under development. If you encounter bugs or
usability issues, please contact us and we'll work to correct them.
1.2. Credits
This Linux ACP Modem driver was ported from the Windows NT?? version of the
driver available from IBM. Many thanks to Keith Frechette, Charles Ball, and
Frank Novak for their technical and support efforts in making this project
possible.
1.3. Where Can I Get the Latest Version of this Driver?
The latest version of this driver is available from [http://www.ibm.com/linux
/ltc/] http://www.ibm.com/linux/ltc/
1.4. Are There Any Other Resources?
Thomas Hood's [http://panopticon.csustan.edu/thood/tp600lnx.htm] Debian GNU/
Linux on IBM ThinkPad 600 and 600x page contains lots of useful information.
1.5. Copyright Notice and Disclaimer
Copyright (c) 2002 IBM Corporation
This document may be reproduced or distributed in any form without prior
permission. Modified versions of this document may be freely distributed,
provided that they are clearly identified as such, and this copyright is
included intact.
This document is provided "AS IS", with no express or implied warranties. Use
the information in this document at your own risk.
1.6. Which Systems are Supported
This version of the ACP Modem driver supports the IBM Thinkpad?? 600E, 600,
and 770 that include on-board ACP modem hardware.
1.7. Features of the Modem
The ACP Modem provides the following features:
��*�Standard asynchronous COM port interface (NS16550A UART compatible)
operation��*�Bell-103/212A, CCITT-V.21/V.22,V.22bis protocols with data from 300 to
2400 bps��*�CCITT-V.32 protocols with data rates of 4800, 9600 uncoded, and 9600 bps
Trellis coded (Optional)��*�CCITT-V.32bis protocols with data rates of 4800, 9600, 12000, and 14400
bps (optional)��*�ITU-T V.34 protocols with data rates from 2400 to 33600 bps.
��*�56K capable modem
��*�Hayes AT Command Set compatibility
��*�DTMF and pulse dialing
��*�Asynchronous error recovery protocol
��*�Error correction via Microcom Network Protocol (MNP) classes 1-4
��*�Error correction via the V.42 error correction standard
��*�MNP class 5 for up to 2x data compression
��*�V.42bis for up to 4x data compression
��*�"Adaptive Rate Negotiation" which provides for "Fallback / Fallforward"
as line quality deteriorates or improvesYour modem contains 56K technology. To take advantage of this technology, you
must first make sure that your Internet Service Provider (ISP) supports a 56K
modem protocol. Significantly higher modem connection speeds, up to 56kbps,
require all-digital transmission connections from your ISP to the line card
in the central office from which your phone line is connected. The actual
connection rate may be limited by the quality of your telephone lines.
Telephone line quality may vary from location to location. Current
regulations limit maximum trasfer rates to 53K. While your modem contains 56K
technology, typical maximum connection rates in the receive direction may be
significantly less than 56K. Currently, 56K capability is for the receive
direction only. The transmit direction uses V.34 technology.
Compilation, Installation, and Startup2.1. Prerequisites
��*�A 2.2.16 series (or later) Linux kernel source tree
��*�An appropriate set of module utilities
��*�gcc version 2.7.x or later
If you are building the ACP Modem driver along with the user space
application, you need to have a complete Linux source tree for your kernel,
not just an up-to-date kernel image.
2.2. Building and Installing Source
Use tar xzvf mwavem-yyyymmdd.tar.gz to unpack the distribution.
Change directories with cd mwavem-yyyymmdd
Use the ./configure command to configure the build options. Issue ./
configure --help to view all of the options. The defaults are probably
okay though.
Note NOTE
� As of mwavem-1.0.3 you must give ./configure the
--enable-mwavedd argument in order to build the driver with the user space application.Use the make command to build all of the ACP Modem binaries.
Note NOTE
� Your gcc package should be at least at the 2.7.x level.
Check your /usr/src/linux/Documentation/Changes file for the minimum version information.Use make install to install the mwavem binary, mwavem.conf configuration,
the extra binary (mostly .dsp) files, and module device driver (if you
specified that it must be built) and to create the /dev/modems/mwave
device node.
2.3. Setting Things Up
In the [WORLDTRADE] section of your mwavem.conf file, set the Country=
parameter to your country access code.
Note NOTE
� The mwavem.conf file is installed in the /usr/local/etc directory unless
you specified otherwise during the build processCountry information (including access codes) are listed in the mwavem.conf
file. For example, for France the following section is present:
[TelephonyCountry List33]
CountryCode=00000021
Name=France
SameAreaRule=0FG
LongDistanceRule=0FG
InternationsalRule=00EFG
To set France to be your configured country in the [WORLDTRADE] section of
mwavem.conf,
+---------------------------------------------------------------------------+
|set Country=33
Comments (0)